The short answer
Visual inspection finds visible damage. Non-destructive evaluation checks condition without loading the anchor to capacity. Proof load testing applies a controlled load to confirm the anchor holds. OSHA leaves the choice to the qualified person, as long as the criteria are scientifically valid.
Visual inspection
- What it checks: corrosion, cracks, deformation, loose or missing fasteners, and the roof membrane and flashing around the anchor
- Strength: fast, and finds most obvious problems
- Limit: it cannot confirm capacity on its own
Non-destructive evaluation
- What it checks: condition without loading the anchor to its limit, for example fastener checks, measuring material loss from corrosion, or examining welds
- Strength: finds hidden deterioration without stressing the anchor
- Limit: the right method depends on the anchor and how it is installed
Proof load testing
- What it checks: the anchor holds a controlled test load, applied with calibrated equipment
- Strength: direct evidence of performance under load
- Limit: tests the anchor at that moment, so it complements inspection rather than replacing it
In a 2019 interpretation, OSHA gave an example it considers acceptable: an anchorage with a 5,000-pound ultimate capacity and a four-to-one safety factor, tested at 2,500 pounds. Testing to the full 5,000 pounds is also acceptable where a consensus standard requires it or the qualified person decides it is necessary.
Methods compared
| Method | Shows | Does not show |
|---|---|---|
| Visual inspection | Visible damage, corrosion, loose parts | Capacity |
| Non-destructive evaluation | Hidden deterioration, fastener and weld condition | Performance under load |
| Proof load test | The anchor holds a set test load | Future deterioration |
Who chooses the method
The qualified person. OSHA accepts any scientifically valid testing criteria, which generally means criteria accepted by an industry consensus group or certified by a registered professional engineer. Ask your inspector which method they used and why, and make sure the report says so. See what an inspection report should contain.